8200 Series Converged Network Adapter and 3200 Series Intelligent Ethernet Adapter Page 79
For every test performed, the diagnostic utility shows the following data:
• Total number of attempts
• Number of successful completions
• Number of failures
You can either perform all tests in succession, or perform only specific tests specified by the preceding
command-line parameters.
You can run additional diagnostics in the CLI as listed in the following table. To determine the
cna_port_inst, issue the qaucli -nic –i command as shown in Table 16.
Windows Diagnostic Test Descriptions
This section provides descriptions of the following Windows diagnostic tests:
• “Hardware Test” on page 79
• “Register Test” on page 79
• “Interrupt Test” on page 80
• “Loopback Test” on page 80
• “Link Test” on page 80
Hardware Test The hardware test checks the status of various hardware blocks, including DMA engines,
receive engine, and on-board processor meta cores.
Register Test The register test performs device register read/write accesses.
Table 16. Running Windows Diagnostic Tests in the CLI
Test Type Command
External Loopback qaucli -nic -extloopback <cna_port_inst> <tests_num> <on_error>
Where <tests_num> specifies the number of tests, 1–65535, and <on_error> is
either 0=Ignore or 1=Abort.
Note: This test requires a pass-through module to be configured for both ports. Test
runs between two ports. Single port loopback is not supported.
Flash qaucli –nic –testflash [cna_port_inst]
Hardware qaucli –nic –testhw [cna_port_inst]
Internal Loopback qaucli -nic -intloopback <cna_port_inst> <tests_num> <on_error>
Where <tests_num> specifies the number of tests, 1–65535, and <on_error> is
either 0=Ignore or 1=Abort
Interrupt qaucli –nic –testinterrupt [cna_port_inst]
Link qaucli -nic -testlink [cna_port_inst]
Ping (IPv4) qaucli -nic -ping <cna_port_inst> <hostname_or_IPv4> [<count> <pock-
et_size> <timeout_ms> <TTL>]
Where the default values are count=5, pocket_size=525, time-
out_ms=1000, and TTL=30
Register qaucli -nic -testregister [cna_port_inst]
Transceiver DMI Data qaucli -nic -trans [cna_port_inst]