3.Notetheorientationofthehot-swapredundantpowersupplyandthenslidethenewhot-swap
redundantpowersupplyintothechassisuntilitsnapsintoposition.
Note:Ifyourservercomeswithonehot-swapredundantpowersupplyinstalledintheredundantpower
supplybay1(thebaynumberismarkedontherearofthechassis)andyouareinstallingasecondary
hot-swapredundantpowersupplytoprovideredundantpower,youneedtoremovetheshieldthat
protectsthebay2first.Savetheshieldforfutureuse.
Figure89.Installingahot-swapredundantpowersupply
4.Ifyouareinstructedtoreturntheoldhot-swapredundantpowersupply,followallpackaginginstructions
anduseanypackagingmaterialsthataresuppliedtoyouforshipping.
5.Toworkwithanotherpieceofhardware,gototheappropriatesection.
Replacingthepowerdistributionboardandcageassembly
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstandingthe“Safetyinformation”
onpageiiiand“Guidelines”onpage85.
Thistopicprovidesinstructionsonhowtoreplacethepowerdistributionboardandcageassembly.
Thistopicappliesonlytoservermodelsthatcomewithhot-swapredundantpowersupplies.
CAUTION:
Hazardousmovingparts.Keepfingersandotherbodypartsaway.
Chapter6.Installing,removing,orreplacinghardware151
Comentarios a estos manuales