Notes:
•Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.
•Useanydocumentationthatcomeswiththeopticaldriveandfollowthoseinstructionsinadditionto
theinstructionsinthistopic.
Toinstallorreplaceanopticaldrive,dothefollowing:
1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectall
powercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedtotheserver.
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.
3.Removetheservercover.See“Removingtheservercover”onpage66.
4.Locatetheoptical-drivebays.See“Frontviewoftheserver”onpage17.Readtheopticaldrive
installationrulesinthistopic.
5.Dependingonwhetheryouareinstallingorreplacinganopticaldrive,dooneofthefollowing:
•Ifyouareinstallingasecondaryopticaldriveintheloweroptical-drivebay,insertafingerintothe
holeasshowntopushtheprotectiveshielduntilitisprojectedfromthefrontofthechassis.Then,
holdtheprotectiveshieldfromthefrontandcompletelyslideitoutofthechassis.
Figure65.Removingtheprotectiveshieldoftheoptical-drivebay
110ThinkServerTD350UserGuideandHardwareMaintenanceManual