1) Grasp the top of the plastic push pins and pull them out of the rivets
(close-up of pin 5 and rivet 6) .
2) Grasp the rivets and pull them out of the mounting holes and set them
to the side.
Note:
If the DIMM air duct in your server is secured with screws,
remove the screws.
b.
Push the air duct up toward the rear of the power-supply cage. When the
locator pins 4 are free of the power-supply cage, you can remove the air
duct from the server.
c. Position the transition duct 1 so that the two tabs are directly over the
slots on the side of the DIMM air duct 3.
d. Slide the transition duct into the slots until it clicks into place.
9. Reinstall the DIMM air duct onto the power-supply cage.
10. Raise the power-supply cage slightly and press and hold the release tab on
the rear power-supply support bracket; then, lower the power-supply structure
into position.
11. Install the rear fan and fan structure on the chassis:
a. Align the clips on the rear fan assembly 1 with the holes in the chassis.
b. Slide the assembly toward the power-supply cage until it stops.
24 ThinkServer TD100 and TD100x Types 4203, 4204, 4205, 4206, 6398, 6399, 6419, and 6429: Installation Guide